Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Feature:
Universal AC input/Full range
Protections: Short circuit / Overload / Over voltage
Cooling by free air convection
Can be installed on DIN rail TS-35 / 7.5 or 15
Built in DC OK active signal
LED indicator for power on
No load power consumption<0.75W
100% full load burn-in test
Specification:
OUTPUT |
|
|||
Model |
MDR-10-5 |
MDR-10-12 |
MDR-10-15 |
MDR-10-24 |
DC Voltage |
5V |
12V |
15V |
24V |
Rated Current |
2A |
0.84A |
0.67A |
0.42A |
Current Range |
0-2A |
0-0.84A |
0-0.67A |
0-0.42A |
Rated Power |
10W |
10W |
10W |
10W |
Ripple & Noise |
80mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
Voltage Adj. Range |
-5%,+10% |
±10% |
±10% |
±10% |
Voltage Tolerance |
±2% |
±1% |
±1% |
±1% |
Setup, Rise, Hold Up Time |
1000ms, 50ms/230VAC 1000ms, 50ms/115VAC at full |
|||
INPUT |
|
|||
Voltage Range |
85 ~ 264VAC 120 ~ 370VDC |
|||
AC Current |
0.88A/115VAC 0.48A/230VAC |
|||
Efficiency |
74% |
84% |
83.5% |
85% |
Inrush Current |
COLD START 35A/115VAC 65A/230VAC |
|||
PROTECTION |
|
|||
Over Load |
105%~160% |
|||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||
Over Voltage |
115%~135% |
|||
Protection type: Shut down o/p voltage, re-power on to recover |
||||
ENVIRONMENT |
|
|||
Working Temp., Humidity |
-10°C~+60°C; 20%~90%RH |
|||
Storage Temp., Humidity |
-40°C~+85°C; 10%~95%RH |
|||
Temp. Coefficient |
±0.03%/°C(0~50°C) |
|||
Vibration |
10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes |
|||
SAFETY |
|
|||
Withstand Voltage |
I/P-O/P: 3KVAC |
|||
Isolation Resistance |
I/P-O/P: 100M Ohms / 500VDC |
|||
STANDARD |
|
|||
Safety Standard |
Design refer to UL60950-1,TUV EN60950-1,EN50178 |
|||
EMC Standard |
Design refer to EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,ENV50204,EN55024,EN61000-6-2,EN61204-3 |
|||
OTHERS |
|
|||
Dimension |
25*93*56mm(L*W*H) |
|||
Weight |
0.15Kg |
|||
Packing |
100pcs/carton |
|||
NOTE |
|
|||
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3. Tolerance: includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into final equipment. The final equipment must be re-confirmed that it still meets EMC directives. |